Sunday, March 10, 2019

Interface reporting multiple alert for the past days related to optical signal?

Hi, Im getting multiple alerts related to optical value which im getting -40dbm(tx/tx) which mean no signal is detected right? But the thing is I'm able to ping and establishment of protocol and doens't have interruption?

Device: C3750E

SFP Module: 1000BaseLX SFP

Is this some sort of bug? or failure of DOm on a spefic interface?

Optical Optical

Temperature Voltage Tx Power Rx Power

Port (Celsius) (Volts) (dBm) (dBm)

--------- ----------- ------- -------- --------

Gi1/0/5 84.6 0.02 -- -40.0 -40.0

%SFF8472-5-THRESHOLD_VIOLATION: Gi1/1: Voltage low alarm; Operating value: 0.02 V, Threshold value: 2.90 V.

%SFF8472-5-THRESHOLD_VIOLATION: Gi1/1/5: Rx power low alarm; Operating value: -40.0 dBm, Threshold value: -22.0 dBm.

%SFF8472-5-THRESHOLD_VIOLATION: Gi1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -10.0 dBm.

%SFF8472-5-THRESHOLD_VIOLATION: Gi1/1: Voltage low alarm; Operating value: 0.02 V, Threshold value: 2.90 V.

sw05.jnb01#sh interface GigabitEthernet1/1 | i pro

GigabitEthernet1/0/5 is up, line protocol is up (connected)

sh interface GigabitEthernet1/1 | i error

0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored

0 output errors, 0 collisions, 0 interface resets