Hello Everyone, I just changed my router on service provider end, and now the user is not getting stable connection from the server. Usually the ping takes 60 ms from server to the end user, now when I changed the router it is taking around >400ms of time. When I use old router, it agains come back to 60ms. I am just made all the configuration of new router similar to the old. Need your help on it. This specific connection is the only problematic part on this router, I have tried changing ports and cables already, still the issue is not resolved. Below is the output of the serial link:
Serial0/0/0 is up, line protocol is up
Hardware is HWIC-Serial
Description: CISCO1 SER0/0 - 'XXXXXXXX'
Internet address is X.X.X.XXX/30
MTU 1500 bytes, BW 252 Kbit/sec, DLY 20000 usec,
reliability 255/255, txload 5/255, rxload 64/255
Encapsulation PPP, LCP Open
Stopped: CDPCP
Open: IPCP, loopback not set
Keepalive set (10 sec)
Last input 00:00:00, output 00:00:08, output hang never
Last clearing of "show interface" counters 12w6d
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 5682
Queueing strategy: fifo
Output queue: 0/40 (size/max)
5 minute input rate 64000 bits/sec, 8 packets/sec
5 minute output rate 5000 bits/sec, 9 packets/sec
833506 packets input, 681752542 bytes, 0 no buffer
Received 0 broadcasts (0 IP multicasts)
62 runts, 0 giants, 0 throttles
2075 input errors, 1993 CRC, 0 frame, 0 overrun, 0 ignored, 20 abort
778407 packets output, 195311494 bytes, 0 underruns
0 output errors, 0 collisions, 227 interface resets
39 unknown protocol drops
0 output buffer failures, 0 output buffers swapped out
1678 carrier transitions
DCD=up DSR=up DTR=up RTS=up CTS=up