Tuesday, July 6, 2021

Alcatel OmniSwitch 9702; Stuck in Certified Mode

Trying to update the AOS on this OmniSwitch 9702. I've tftp'd the files onto the /flash/working/ directory and am now unable to copy those files from the working directory to the certified directory. I seem to be stuck in certified mode.

reload working no rollback-timeout
-With this command; the switch reboots but doesn't boot from the working directory.

copy working certified
-Command doesn't work since I am in stuck in certified mode
--"ERROR: Invalid request, CERTIFY requested while running on certified"

write memory
-Unable to use due to directory
--"ERROR: Write memory is not permitted when switch is running in certified mode"

Modify
-The only available syntax after this command is "boot parameters"

How do I switch the running directory to "working" rather than "certified"?

Unable to post configs but can provide as much info as needed:

Current AOS version: 6.4.3.520.R01
Upgrade to: 6.4.3.884.R01

show running-directory:
Running CMM: Primary
CMM Mode: Mono CMM
Current CMM Slot: A
Running configuration: Certified
Certify/Restore Status: Certify needed

SO, the question is, how do I change the running configuration to Certified?