I'm deploying a switch to a new building and I cannot get them to see each other (no activity light, no ping, no lldp).
The connection goes (from MDF to IDF), Ruckus ICX 7150 --> 1G Brocade SX SFP ---> 50/125 MM patch cable --> MM 50/125 fiber drop --> 50/125 MM patch cable --> 1G Brocade SX SFP --> Ruckus ICX 7150
Things I've have done:
- Test fiber drop lines for signal and correct polarity (-6.41db)
- Test a different patch cable in the IDF (I should swap out cables in the MDF to be sure, so that's next on my list)
- Swap out and test the MDF switch with a different and known to be working HP switch and matching HP SFP
- Make sure ports are enabled
- Make sure STP is not blocking port (both STP and 802.1w are disabled on both ends.
- Made sure switches can see the SFP installed.
- Both Ruckus switches are on same firmware
- Vlans are tagged the same on both ends on the port
- Logs are not showing anything indicating errors, blocking ports, or anything else as far as I can see
We have made this work over other fiber drops so I know it can be done. I feel like I'm just missing something easy and stupid. Any ideas where I could try troubleshooting would be appreciated!
Thanks.