I understand on a Brocade TurboIron 24x there are two ways to create a trunk:
Method 1: trunk ethe 1 to 2
Method 2: int e 1 to 2
link-aggregate configure key <key id>
link-aggregate active
I have both ways done on two TurboIron 24x. Method 1 above for two 10gbe cables between switches, and Method 2 for two 10gbe fiber between a switch and a Tegile storage array serving NFS shares.
Issue I have is on switch 2, the method 1 (static trunk) between switches shows the second port, port 19 blocked, and true the LED on that port on the switch is not illuminated. However on switch 1, this same port 19 shows in a "Forward" state and sure enough the LED is lit solid on that physical switch port. How can the link be forward on one switch and blocked on the other, if they are configured the same? Thinking it was a bad Twinax cable, I replaced port 19 between switches with an 850nm SFP+ and a short fiber optic cable. I had the same result where switch 1 showed the port forwarding but switch 2 showed the port blocked.
Here's an output of show trunk on switch 1
Configured trunks: Trunk ID: 18 Hw Trunk ID: 1 Ports_Configured: 2 Primary Port Monitored: Jointly Ports PortName Port_Status Monitor Rx_Mirr Tx_Mirr Monitor_Dir 18 10gbe1* enable off N/A N/A N/A 19 none enable off N/A N/A N/A Trunk ID: 21 Hw Trunk ID: 2 Ports_Configured: 2 Primary Port Monitored: Jointly Ports PortName Port_Status Monitor Rx_Mirr Tx_Mirr Monitor_Dir 21 Tegile* enable off N/A N/A N/A 22 Tegile* enable off N/A N/A N/A Operational trunks: Trunk ID: 18 Hw Trunk ID: 1 Duplex: Full Speed: 10G Tag: No Priority: level0 Active Ports: 2 Ports Link_Status port_state 18 active Forward 19 active Forward Trunk ID: 21 Hw Trunk ID: 2 Duplex: Full Speed: 10G Tag: No Priority: level0 Active Ports: 2 Ports Link_Status port_state LACP_Status 21 active Forward ready 22 active Forward ready
Here's an output of show trunk on switch 2
Configured trunks: Trunk ID: 18 Hw Trunk ID: 1 Ports_Configured: 2 Primary Port Monitored: Jointly Ports PortName Port_Status Monitor Rx_Mirr Tx_Mirr Monitor_Dir 18 10gbe1* enable off N/A N/A N/A 19 none enable off N/A N/A N/A Trunk ID: 21 Hw Trunk ID: 2 Ports_Configured: 2 Primary Port Monitored: Jointly Ports PortName Port_Status Monitor Rx_Mirr Tx_Mirr Monitor_Dir 21 Tegile* enable off N/A N/A N/A 22 Tegile* enable off N/A N/A N/A Operational trunks: Trunk ID: 18 Hw Trunk ID: 1 Duplex: Full Speed: 10G Tag: No Priority: level0 Active Ports: 1 Ports Link_Status port_state 18 active Forward 19 down Blocked Trunk ID: 21 Hw Trunk ID: 2 Duplex: Full Speed: 10G Tag: No Priority: level0 Active Ports: 2 Ports Link_Status port_state LACP_Status 21 active Forward ready 22 active Forward ready
Here is how that trunk is configured on both switches... at the very top of the config on both it shows:
trunk ethe 18 to 19 port-name "10gbe1 to 10gbe2 A" ethernet 18
Here's how the trunk to the operational Tegile storage array looks on switch 1
interface ethernet 21 port-name Tegile Controller A Port 1 no spanning-tree link-aggregate configure timeout short link-aggregate configure key 21001 link-aggregate active ! interface ethernet 22 port-name Tegile Controller A Port 2 no spanning-tree link-aggregate configure key 21001 link-aggregate configure timeout short link-aggregate active
And how the trunk to the other Tegile storage array controller looks on switch 2
interface ethernet 21 port-name Tegile Controller B Port 1 no spanning-tree link-aggregate configure timeout short link-aggregate configure key 21002 link-aggregate active ! interface ethernet 22 port-name Tegile Controller B Port 2 no spanning-tree link-aggregate configure key 21002 link-aggregate configure timeout short link-aggregate active
The issue is that yesterday I failed over the Tegile storage array from controller A to controller B. This means the NFS storage traffic to 8 ESXi servers would now originate off of switch 2, so that traffic would have to traverse the switch 2 to switch 1 trunk (ports 18 and 19) back to the "active" vmware adapters. Those vmware storage adapters remain active unless a link failure, then and only then would vmware try to talk off of switch 2. I can't use becon probing instead of link state for failover because I read for stability you need 3 adapters for this and I do not have a third adapter. So the issue I had was the two IP's on the Tegile storage array claimed to be moved over to controller B, but vmware could only ping ONE of those IP's... all storage mapped via the second IP went (inaccessible) and SSH to an ESXi server revealed I could only ping one of the Tegile IP's. So I'm trying to rule out a networking issue because so far Tegile took our config and put it on one of their lab systems and both IP's we have programmed moved properly to their second controller. However the difference is they just spun their test system up for us, whereas we have 400+ days of uptime on our controller, so they do suggest I reboot controller B and try again... but rather than cause another outage I want to investigate why this inter switch trunk has one port showing blocked only on one switch.
We have money in the budget to replace the brocades with Arista, however I only have enough money to do 1 Arista switch and then we would be running just 1 switch, or 2 switches but two different vendors (1 arista primary, 1 brocade backup). Next year I can request more money and if approved get a second Arista switch.
Thanks for your info. I'm used to Cisco and Extreme Networks. The brocade foundry stuff seems a little foreign to me and limited.
No comments: