I have two cisco nexus 3064PQ running in vPC domain for multi-chassis LAg, these switches connected to my HP6120XG (c7000 blade center), life was good last 1 week everything was working fine but today i have noticed vpc is down so when i started looking i noticed following.
LACP lost all partners and i am seeing FCS RX error, this is not in production yet so there is almost zero traffic but where this drops coming also i am seeing same behavior on both HP6120xG switch in c7000, how can both switch go bad same time?
Duplex are auto and i have many other blades running with same config and they all are happy.
# show lacp
LACP
PORT LACP TRUNK PORT LACP LACP
NUMB ENABLED GROUP STATUS PARTNER STATUS
---- ------- ------- ------- ------- -------
18 Active Trk1 Up No Success
19 Active Trk1 Up No Success
20 Active Trk1 Up No Success
21 Active Trk1 Up No Success
23 Active 23 Down No Success
24 Active 24 Down No Success
# sh interfaces
Status and Counters - Port Counters
Flow Bcast
Port Total Bytes Total Frames Errors Rx Drops Rx Ctrl Limit
------- -------------- -------------- ------------ ------------ ---- -----
1 0 0 0 0 off 0
2 0 0 0 0 off 0
3 0 0 0 0 off 0
4 0 0 0 0 off 0
5 0 0 0 0 off 0
6 0 0 0 0 off 0
7 0 0 0 0 off 0
8 1,326,944 2925 0 0 on 0
9 1,326,944 2925 0 0 on 0
10 1,327,200 2927 0 0 off 0
11 327,772,440 72,212,498 0 0 on 0
12 2,316,131,200 36,189,550 0 0 on 0
13 0 0 0 0 off 0
14 0 0 0 0 off 0
15 1,327,355 2929 0 0 on 0
16 0 0 0 0 off 0
17 0 0 0 0 off 0
18-Trk1 5,602,138 78,160 0 78,122 off 0
19-Trk1 449,983,864 4,448,422 0 4,447,415 off 0
20-Trk1 374,766,828 4,193,334 0 4,192,785 off 0
21-Trk1 455,331,402 4,298,985 0 4,298,115 off 0
22 0 0 0 0 off 0
23 0 0 0 0 off 0
24 0 0 0 0 off 0