Got complaints from remote users that their SSH sessions were disconnecting mid jobs and I decided to investigate and noticed the 10g L3 link between our core switch (Te7/1) and our distribution switch (Te7/3) was flapping for a millisecond and OSPF adjacency between them as a result was flapping as well.
Both are cisco 6807XL, there is a tap between this link though.
looking at the logs on the link on the dist switch, it goes down and up for a millisecond.
Jan 3 08:47:42.661 pst: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet7/3, changed state to down
Jan 3 08:47:43.797 pst: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet7/3, changed state to up
Jan 3 08:52:45.627 pst: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet7/3, changed state to down
Jan 3 08:52:46.703 pst: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet7/3, changed state to up
Jan 3 09:04:58.480 pst: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet7/3, changed state to down
Jan 3 09:04:59.588 pst: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet7/3, changed state to up
but this millisecond is enough to bring down the OSPF adjancency between them, as shown in the logs from the core below...
Jan 3 08:47:45.805 pst: %OSPFv3-5-ADJCHG: Process 10343, Nbr 12.9.2.24 on TenGigabitEthernet7/1 from LOADING to FULL, Loading Done
Jan 3 08:47:48.409 pst: %OSPF-5-ADJCHG: Process 10343, Nbr 12.9.2.24 on TenGigabitEthernet7/1 from LOADING to FULL, Loading Done
Jan 3 08:52:46.707 pst: %OSPF-5-ADJCHG: Process 10343, Nbr 12.9.2.24 on TenGigabitEthernet7/1 from LOADING to FULL, Loading Done
Jan 3 08:52:48.791 pst: %OSPFv3-5-ADJCHG: Process 10343, Nbr 12.9.2.24 on TenGigabitEthernet7/1 from LOADING to FULL, Loading Done
Jan 3 09:04:59.592 pst: %OSPF-5-ADJCHG: Process 10343, Nbr 12.9.2.24 on TenGigabitEthernet7/1 from LOADING to FULL, Loading Done
Jan 3 09:05:01.592 pst: %OSPFv3-5-ADJCHG: Process 10343, Nbr 12.9.2.24 on TenGigabitEthernet7/1 from LOADING to FULL, Loading Done
I'm trying to figure out why it's flapping. I have checked the physical links and did a "sh int te7/1 transceiver" to see the optical Tx/Rx power and they are within normal range.
on the dist switch(Te7/3):
Temp (celsius) 34.8
Volt (v) N/A
Current (mA) 35.5
Optical Tx Power (dBm) -0.2
Optical Rx Power (dBm)-5.5
on the core(te7/1):
Temp (celsius) 29.4
Volt (v) 3.29
Current (mA) 34.4
Optical Tx Power (dBm) -0.6
Optical Rx Power (dBm)-3.6
or could this be caused by the tap that is in the middle?