I am using the track feature for the intelligence on when a circuit goes down. When circuit 1 goes down it inserts the route for circuit 2 properly. However when circuit 1 comes back online it does not reinsert that route. So I am stuck with asymmetrical routing.I manually clear the route and it will then insert the route for circuit 1 and traffic will flow properly then.