Sunday, December 10, 2017

WAN LAGG

Can anyone poke holes in this design?

The design is intentionally avoiding additionally muxing and optical gear as the dark fiber is not ours. We are assigned wide-width 1310nm on our partner’s mux.

Sites: A, B, H

Under normal conditions sites A<—>B carry 22Gbps better each other.

Site H has a single optical path to both A & B but does not have an optical path through A to B nor vice versa.

Sites A & B have two physically diverse 40 Gbps paths: East (10Km) & West(20Km)

Proposal: LAGG AB-East and AB-West together. This should provide protection of a link failure between A and B. This should also provide plenty of capacity if A-H fails or B-H fails.

Specificity, I’m curious if anyone sees an issue LAGGing a 20Km path with a 35Km path.